Variation in Ultraviolet (UV-C) Contact Time Using Solar Panels on the Reduction of Total Coliform in Clean Water at PT. X, Sumedang Regency

https://doi.org/10.33860/bjkl.v5i2.4219

Authors

  • Nina Kaniawati Department of Environmental Health, Poltekkes Kemenkes Bandung, West Java, Indonesia
  • Muhamad Iqbal Department of Environmental Health, Poltekkes Kemenkes Bandung, West Java, Indonesia
  • Lubis Bambang Purnama Department of Environmental Health, Poltekkes Kemenkes Bandung, West Java, Indonesia
  • Neneng Yety Hanurawaty Department of Environmental Health, Poltekkes Kemenkes Bandung, West Java, Indonesia

Keywords:

Clean water, coliform, ultraviolet-c, solar panels, contact time

Abstract

Background: Water contaminated with Total Coliform can lead to diseases such as diarrhea, cholera, dysentery, and other gastrointestinal infections. Preliminary testing of water at PT. X revealed a Total Coliform count of 56 CFU/100 ml, surpassing the safe threshold for clean water. This study aims to evaluate the effect of varying ultraviolet (UV-C) light contact times—90, 120, and 150 seconds—on the reduction of Total Coliform in clean water.

Methods: An experimental post-test with a control group design was used. The sample size was determined by the number of treatment groups and repetitions, resulting in a total of 24 samples. Grab sampling was employed for sample collection.

Results: The average Total Coliform count in the control group was 56 CFU/100 ml. After UV-C treatment, the counts decreased to 32 CFU/100 ml at 90 seconds, 11 CFU/100 ml at 120 seconds, and 0 CFU/100 ml at 150 seconds. One-way ANOVA analysis yielded a p-value of 0.000, indicating a significant effect of UV-C contact time on the reduction of Total Coliform in clean water at PT. X, Sumedang Regency.

Conclusion: Disinfection using UV-C light with a contact time of 150 seconds is recommended

References

A., S., As, Z. A., & Setiadi, G. (2014). Efektivitas “Portable UV Disinfection” dalam Menurunkan Angka Bakteri (Escherichia Coli Spp) pada Air Minum. Jurnal Kesehatan Lingkungan: Jurnal Dan Aplikasi Teknik Kesehatan Lingkungan, 11(2), 223–230. https://doi.org/10.31964/JKL.V11I2.15

Aba, L., Mulidin, M., Sety, L. O. M., Yuniar, N., Sahidin, L. O., Andimbara, L. O., & Irfan, I. (2023). Penyuluhan Pemanfaatan Air Bersih dan Sosialisasi Bimbingan Teknis Pengolahan Air Bersih dengan Metode Aerasi-Filtrasi untuk Meningkatkan Derajat Kesehatan Masyarakat. Indonesia Berdaya, 5(1), 119–126. https://doi.org/10.47679/ib.2024661

Abboushi, B., Rodriguez-Feo Bermudez, E., Tuenge, J., & Arnold, G. (2025). GUV Installations Demonstrate Effectiveness and Exposure Safety in Field Settings. Environmental Science & Technology, 59(17), 8640–8650. https://doi.org/10.1021/ACS.EST.4C10774

Backer, H. D., Derlet, R. W., & Hill, V. R. (2024). Wilderness Medical Society Clinical Practice Guidelines on Water Treatment for Wilderness, International Travel, and Austere Situations: 2024 Update. Wilderness and Environmental Medicine, 35(1_suppl), 45S-66S. https://doi.org/10.1177/10806032231218722

Banseka, Y. J., & Tume, S. J. P. (2024). Coliform Bacteria Contamination of Water Resources and Implications on Public Health in Fako Division, South West Region, Cameroon. Advances in Environmental and Engineering Research 2024, Vol. 5, 010, 5(2), 1–13. https://doi.org/10.21926/AEER.2402010

Bylund, J., Toljander, J., Lysén, M., Rasti, N., Engqvist, J., & Simonsson, M. (2017). Measuring sporadic gastrointestinal illness associated with drinking water - An overview of methodologies. Journal of Water and Health, 15(3), 321–340. https://doi.org/10.2166/WH.2017.261

Dinny, H. N. A., Teguh, P. B., Yosephina, S. A., & Agus, S. S. (2019). Variasi Jarak Penyinaran Lampu Uv Terhadap Penurunan Angka Kuman Pada Alat Makan. Jurnal Riset Kesehatan Poltekkes Depkes Bandung, 11(2), 150–154. https://doi.org/https://doi.org/10.34011/juriskesbdg.v11i2.724

Dramicanin, M. D., Brik, M. G., Antic, Z., Banica, R., Mosoarca, C., Dramicanin, T., … Suta, M. (2025). Pr3+ Visible to Ultraviolet Upconversion for Antimicrobial Applications. Nanomaterials 2025, Vol. 15, Page 562, 15(7), 562. https://doi.org/10.3390/NANO15070562

Ersel, M. (2015). Water and sanitation standards in humanitarian action. Turkish Journal of Emergency Medicine, 15(Suppl 1), 27–33. https://doi.org/10.5505/1304.7361.2015.48753

Gao, Y., Zhao, X., & Li, C. (2025). The evolution of irreversible cell differentiation under cell death effect. PloS One, 20(8). https://doi.org/10.1371/journal.pone.0315255

Kementerian Kesehatan. (2023). Permenkes No. 2 Tahun 2023 tentang Kesehatan Lingkungan, yang mengatur standar baku mutu dan persyaratan kesehatan untuk berbagai media lingkungan. Kemenkes Republik Indonesia, (55), 1–175.

Khan, S., Mumtaj, Z. A., Khan, A. R., Ahmad, N., & Alqahtani, D. A. (2025). A review of conventional and non-conventional disinfection methods for treating potable water and wastewater. International Journal of Chemical Reactor Engineering, 23(8), 895–916. https://doi.org/10.1515/IJCRE-2024-0235/Machinereadablecitation/Ris

Korajkic, A., McMinn, B. R., & Harwood, V. J. (2018). Relationships between microbial indicators and pathogens in recreational water settings. International Journal of Environmental Research and Public Health, 15(12). https://doi.org/10.3390/IJERPH15122842

Kumar, N., & Tripathi, K. (2025). Effects of ultraviolet (UV) radiation on microbial growth: Mechanisms, responses, and applications. Biotechnology Lab Techniques: Culture Media, Microscopy, and Microbial Analysis, 57–59. https://doi.org/10.70593/978-93-49307-52-0_7

Labina, H. F., & Purnomo, Y. S. (2022). Penyisihan Bakteri E. Coli Menggunakan Radiasi Sinar Ultraviolet Dan Semikonduktor Tio2 Pada Air Sumur Desa Kenongo, Sidoarjo. Envirous, 2(2). https://doi.org/10.33005/envirous.v2i2.95

Li, D., & Liu, S. (2019). Water Quality Monitoring in Aquaculture. Water Quality Monitoring and Management, 303–328. https://doi.org/10.1016/B978-0-12-811330-1.00012-0

Navratinova, S., & Tri, J. (2019). Hubungan Desinfeksi Sinar Ultraviolet (UV) dengan Kualitas Bakteriologi Air minum pada Depot Air Minum Isi Ulang (DAMIU) (Studi di Kecamatan Pontianak Selatan Kota Pontianak). Jurnal Kesehatan Masyarakat, 7(1), 2356–3346. https://doi.org/https://doi.org/10.14710/jkm.v7i1.23011

Ningsih, D. U. R., Karmini, M., & Hidayah, N. (2021). Perbedaan Daya Lampu Ultraviolet-C Terhadap Penurunan Jumlah Bakteri Coliform Pada Air Bersih Di Industri Logam. Jurnal Riset Kesehatan Poltekkes Depkes Bandung, 13(2), 422–426. https://doi.org/10.34011/juriskesbdg.v13i2.1931

Permenkes. Permenkes Nomor 32 Tahun 2017 Tentang Standar Baku Mutu Kesehatan Lingkungan Dan Persyaratan Kesehatan Air Untuk Keperluan Higiene Sanitasi, Kolam Renang, Solus Per Aqua dan Pemandian Umum. , Peraturan Menteri kesehatan Republik Indonesia § (2017).

Saputri, E. T., & Efendy, M. (2020). Kepadatan bakteri coliform sebagai indikator pencemaran biologis di perairan p. Juvenil:Jurnal Ilmiah Kelautan Dan Perikanan, 1(2), 243–249. https://doi.org/10.21107/juvenil.v1I2.7579

Sari, D. I., Septiati, Y. A., & Setyoko, S. (2021). Perbedaan Lama Penyinaran Uv-C Terhadap Reduksi Jumlah Escherichia Coli Pada Air Bersih Dapur Pt. Xyz. Jurnal Kesehatan Siliwangi, 2(2), 537–542. https://doi.org/10.34011/jks.v2i2.719

Sliney, D. H., & Stuck, B. E. (2021). A Need to Revise Human Exposure Limits for Ultraviolet UV-C Radiation†. Photochemistry and Photobiology, 97(3), 485–492. https://doi.org/10.1111/PHP.13402

Some, S., Mondal, R., Mitra, D., Jain, D., Verma, D., & Das, S. (2021). Microbial pollution of water with special reference to coliform bacteria and their nexus with environment. Energy Nexus, 1, 100008. https://doi.org/10.1016/J.NEXUS.2021.100008

Sultana, R., Nahar, N., Luby, S. P., Swarna, S. T., Gurley, E. S., Tamason, C. C., … Jensen, P. K. M. (2022). Measuring Water Quantity Used for Personal and Domestic Hygiene and Determinants of Water Use in a Low-Income Urban Community. International Journal of Environmental Research and Public Health, 19(23). https://doi.org/10.3390/ijerph192315656

Syafarida, U. Y., Jati, D. R., & Sulastri, A. (2022). Analisis Hubungan Konstruksi Sumur Gali dan Sanitasi Lingkungan Terhadap Jumlah Bakteri Coliform Dalam Air Sumur Gali (Studi Kasus: Desa PAL IX, Kecamatan Sungai Kakap). Jurnal Ilmu Lingkungan, 20(3), 437–444. https://doi.org/10.14710/jil.20.3.437-444

Thorpe, D., McKinlay, M., Richards, J., Sang, K., & Stewart, M. E. (2024). The Lived Experience of Autistic Adults in Employment: A Systematic Search and Synthesis. Autism in Adulthood : Challenges and Management, 6(4), 495–509. https://doi.org/10.1089/aut.2022.0114

Tripathi, D. R. (2023). Safe Drinking Water-Threats of Pollution to Potable Water For The Community. Journal of Survey in Fisheries Sciences. https://doi.org/10.53555/G86WES45

Widyawati. (2019). Kebutuhan Air Bersih Bagi Manusia. Penerbit Citra Ilmu.

Published

2025-10-27

How to Cite

Kaniawati, N., Iqbal, M., Bambang Purnama, L., & Yety Hanurawaty, N. (2025). Variation in Ultraviolet (UV-C) Contact Time Using Solar Panels on the Reduction of Total Coliform in Clean Water at PT. X, Sumedang Regency. Banua: Jurnal Kesehatan Lingkungan, 5(2), 83–92. https://doi.org/10.33860/bjkl.v5i2.4219

Issue

Section

Articles